THE EFFECTS OF CHANGES IN CELL GEOMETRY AND OPERATING CONDITIONS ON PERFORMANCE IN A PEM FUEL CELL
Muhammed Salih Cellek1, Tolga Demircan2
1Department of Mechanical Engineering, Ankara Yıldırım Beyazıt University, 06010, Ankara, Turkey
2Department of Mechanical Engineering, Kırıkkale University, 71450, Kirikkale, Turkey
Correspondence:  Muhammed Salih Cellek,
Email: mscel71@gmail.com
Received: 3 August 2026   • Accepted: 25 October 2026
Abstract
This study examined the effects of different fuel cell geometries and operating conditions on fuel cell performance. Taking into account the applications and operating conditions of fuel cells, new geometric configurations have been developed that could serve as alternatives to the traditional planar fuel cell design. In this context, designs have been created in triangular, quadrilateral, pentagonal, and hexagonal configurations. Numerical analyses were performed for each design under varying temperatures, pressures, and stoichiometric ratios to compare the responses of the fuel cells to varying operating conditions. Among the fuel cell geometries examined in this study, the highest current density and power performance were achieved in the fuel cell with a quadrilateral geometry, while the lowest current density and power performance were observed in the fuel cell with a triangular geometry. It was also determined that temperature changes have a greater impact on fuel cell performance than pressure and the stoichiometric ratio; specifically, when the temperature rises above 363 K, fuel cell performance decreases by approximately 44%–56%. Furthermore, it was observed that as the pressure increased to 1.4 atm and the stoichiometric ratio rose above 1.5, the change in fuel cell performance remained quite limited. In addition, under varying operating conditions, the most consistent change in performance was observed in the quadrilateral fuel cell, while the most inconsistent change in performance was observed in the triangular fuel cell. In conclusion, based on the analyses carried out, it has been determined that the quadrilateral, pentagonal and hexagonal fuel cells analysed exhibit performance levels closely comparable to the traditional planar design. Thus, considering the geometric structure of the device in which the fuel cell is to be used and any potential volumetric constraints, it is assessed that these new geometries could be highly viable alternatives to the standard planar fuel cell. Furthermore, considering variable operating conditions, the quadrilateral is particularly distinguished by its remarkable performance stability.
TOOLS
Share :
Facebook Twitter Linked In Google+ Line it
METRICS Graph View
  • 0 Crossref
  •   Scopus
  • 156 View
  • 19 Download
Related articles in J. Electrochem. Sci. Technol


ABOUT
ARTICLE CATEGORY

Browse all articles >

BROWSE ARTICLES
AUTHOR INFORMATION
Editorial Office
E-mail: journal@kecs.or.kr    Tel: +82-2-568-9392               

Copyright © 2026 by The Korean Electrochemical Society.

Developed in M2PI

Close layer
prev next